UdSeparation
SCPI Command :
CONFigure:LTE:SIGNaling<instance>:RFSettings:SCC<Carrier>:UDSeparation
- class UdSeparationCls[source]
UdSeparation commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(secondaryCompCarrier=SecondaryCompCarrier.Default) int [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:RFSettings:SCC<Carrier>:UDSeparation value: int = driver.configure.rfSettings.scc.udSeparation.get(secondaryCompCarrier = repcap.SecondaryCompCarrier.Default)
Configures the UL/DL separation. For most operating bands, this setting is fixed.
- param secondaryCompCarrier:
optional repeated capability selector. Default value: CC1 (settable in the interface ‘Scc’)
- return:
frequency: numeric UL/DL separation Range: see table , Unit: Hz
- set(frequency: int, secondaryCompCarrier=SecondaryCompCarrier.Default) None [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:RFSettings:SCC<Carrier>:UDSeparation driver.configure.rfSettings.scc.udSeparation.set(frequency = 1, secondaryCompCarrier = repcap.SecondaryCompCarrier.Default)
Configures the UL/DL separation. For most operating bands, this setting is fixed.
- param frequency:
numeric UL/DL separation Range: see table , Unit: Hz
- param secondaryCompCarrier:
optional repeated capability selector. Default value: CC1 (settable in the interface ‘Scc’)