Csirs
SCPI Commands :
CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:MODE
CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:POFFset
- class CsirsCls[source]
Csirs commands group definition. 2 total commands, 0 Subgroups, 2 group commands
- get_mode() CsirsMode [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:MODE value: enums.CsirsMode = driver.configure.downlink.pcc.csirs.get_mode()
Selects a configuration mode for the used CSI-RS power offset.
- return:
mode: ACSirs | MANual ACSirs The used power offset matches the signaled value. For configuration of the signaled value, see method RsCmwLteSig.Configure.Connection.Scc.Tm.Csirs.Power.set. MANual The used power offset is independent from the signaled value. For configuration of the used power offset, see method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Poffset.set.
- get_poffset() float [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:POFFset value: float = driver.configure.downlink.pcc.csirs.get_poffset()
Sets the EPRE of the PDSCH relative to the EPRE of the CSI reference signal. The value is only used for method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Mode.set = ACSirs.
- return:
offset: numeric Range: -30 dB to 8 dB, Unit: dB
- set_mode(mode: CsirsMode) None [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:MODE driver.configure.downlink.pcc.csirs.set_mode(mode = enums.CsirsMode.ACSirs)
Selects a configuration mode for the used CSI-RS power offset.
- param mode:
ACSirs | MANual ACSirs The used power offset matches the signaled value. For configuration of the signaled value, see method RsCmwLteSig.Configure.Connection.Scc.Tm.Csirs.Power.set. MANual The used power offset is independent from the signaled value. For configuration of the used power offset, see method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Poffset.set.
- set_poffset(offset: float) None [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:POFFset driver.configure.downlink.pcc.csirs.set_poffset(offset = 1.0)
Sets the EPRE of the PDSCH relative to the EPRE of the CSI reference signal. The value is only used for method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Mode.set = ACSirs.
- param offset:
numeric Range: -30 dB to 8 dB, Unit: dB