Csirs

SCPI Commands :

CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:MODE
CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:POFFset
class CsirsCls[source]

Csirs commands group definition. 2 total commands, 0 Subgroups, 2 group commands

get_mode() CsirsMode[source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:MODE
value: enums.CsirsMode = driver.configure.downlink.pcc.csirs.get_mode()

Selects a configuration mode for the used CSI-RS power offset.

return:

mode: ACSirs | MANual ACSirs The used power offset matches the signaled value. For configuration of the signaled value, see method RsCmwLteSig.Configure.Connection.Scc.Tm.Csirs.Power.set. MANual The used power offset is independent from the signaled value. For configuration of the used power offset, see method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Poffset.set.

get_poffset() float[source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:POFFset
value: float = driver.configure.downlink.pcc.csirs.get_poffset()

Sets the EPRE of the PDSCH relative to the EPRE of the CSI reference signal. The value is only used for method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Mode.set = ACSirs.

return:

offset: numeric Range: -30 dB to 8 dB, Unit: dB

set_mode(mode: CsirsMode) None[source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:MODE
driver.configure.downlink.pcc.csirs.set_mode(mode = enums.CsirsMode.ACSirs)

Selects a configuration mode for the used CSI-RS power offset.

param mode:

ACSirs | MANual ACSirs The used power offset matches the signaled value. For configuration of the signaled value, see method RsCmwLteSig.Configure.Connection.Scc.Tm.Csirs.Power.set. MANual The used power offset is independent from the signaled value. For configuration of the used power offset, see method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Poffset.set.

set_poffset(offset: float) None[source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:DL[:PCC]:CSIRs:POFFset
driver.configure.downlink.pcc.csirs.set_poffset(offset = 1.0)

Sets the EPRE of the PDSCH relative to the EPRE of the CSI reference signal. The value is only used for method RsCmwLteSig.Configure.Downlink.Scc.Csirs.Mode.set = ACSirs.

param offset:

numeric Range: -30 dB to 8 dB, Unit: dB