Downlink<Stream>
RepCap Settings
# Range: S1 .. S2
rc = driver.configure.connection.scc.rmc.rbPosition.downlink.repcap_stream_get()
driver.configure.connection.scc.rmc.rbPosition.downlink.repcap_stream_set(repcap.Stream.S1)
SCPI Command :
CONFigure:LTE:SIGNaling<instance>:CONNection:SCC<Carrier>:RMC:RBPosition:DL<Stream>
- class DownlinkCls[source]
Downlink commands group definition. 1 total commands, 0 Subgroups, 1 group commands Repeated Capability: Stream, default value after init: Stream.S1
- get(secondaryCompCarrier=SecondaryCompCarrier.Default, stream=Stream.Default) DownlinkRsrcBlockPosition [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:CONNection:SCC<Carrier>:RMC:RBPosition:DL<Stream> value: enums.DownlinkRsrcBlockPosition = driver.configure.connection.scc.rmc.rbPosition.downlink.get(secondaryCompCarrier = repcap.SecondaryCompCarrier.Default, stream = repcap.Stream.Default)
- Selects the position of the allocated downlink resource blocks. Set the same value for both streams of a carrier.
INTRO_CMD_HELP: Depending on other settings, only a subset of the listed values is allowed, see:
‘Scheduling type RMC’
‘Scheduling type RMC for eMTC’
‘Scheduling type RMC for LAA’
- param secondaryCompCarrier:
optional repeated capability selector. Default value: CC1 (settable in the interface ‘Scc’)
- param stream:
optional repeated capability selector. Default value: S1 (settable in the interface ‘Downlink’)
- return:
position: LOW | HIGH | P5 | P10 | P23 | P35 | P48
- set(position: DownlinkRsrcBlockPosition, secondaryCompCarrier=SecondaryCompCarrier.Default, stream=Stream.Default) None [source]
# SCPI: CONFigure:LTE:SIGNaling<instance>:CONNection:SCC<Carrier>:RMC:RBPosition:DL<Stream> driver.configure.connection.scc.rmc.rbPosition.downlink.set(position = enums.DownlinkRsrcBlockPosition.HIGH, secondaryCompCarrier = repcap.SecondaryCompCarrier.Default, stream = repcap.Stream.Default)
- Selects the position of the allocated downlink resource blocks. Set the same value for both streams of a carrier.
INTRO_CMD_HELP: Depending on other settings, only a subset of the listed values is allowed, see:
‘Scheduling type RMC’
‘Scheduling type RMC for eMTC’
‘Scheduling type RMC for LAA’
- param position:
LOW | HIGH | P5 | P10 | P23 | P35 | P48
- param secondaryCompCarrier:
optional repeated capability selector. Default value: CC1 (settable in the interface ‘Scc’)
- param stream:
optional repeated capability selector. Default value: S1 (settable in the interface ‘Downlink’)
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.connection.scc.rmc.rbPosition.downlink.clone()