Rperiod

SCPI Command :

SENSe:LTE:SIGNaling<instance>:CQIReporting:SCC<Carrier>:RPERiod
class RperiodCls[source]

Rperiod commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(secondaryCompCarrier=SecondaryCompCarrier.Default) int[source]
# SCPI: SENSe:LTE:SIGNaling<instance>:CQIReporting:SCC<Carrier>:RPERiod
value: int = driver.sense.cqiReporting.scc.rperiod.get(secondaryCompCarrier = repcap.SecondaryCompCarrier.Default)

Queries the reporting period Np in subframes, resulting from the configured ‘cqi-pmi-ConfigIndex’.

param secondaryCompCarrier:

optional repeated capability selector. Default value: CC1 (settable in the interface ‘Scc’)

return:

period: decimal Range: 1 to 160