Uplink
SCPI Commands :
SENSe:LTE:SIGNaling<instance>:CONNection:ETHRoughput:UL[:PCC]
SENSe:LTE:SIGNaling<instance>:CONNection:ETHRoughput:UL:ALL
- class UplinkCls[source]
Uplink commands group definition. 3 total commands, 1 Subgroups, 2 group commands
- get_all() float [source]
# SCPI: SENSe:LTE:SIGNaling<instance>:CONNection:ETHRoughput:UL:ALL value: float = driver.sense.connection.ethroughput.uplink.get_all()
Returns the expected maximum uplink throughput (averaged over one frame) for the sum of all component carriers. The throughput is calculated for the currently selected scheduling type.
- return:
throughput: float Unit: Mbit/s
- get_pcc() float [source]
# SCPI: SENSe:LTE:SIGNaling<instance>:CONNection:ETHRoughput:UL[:PCC] value: float = driver.sense.connection.ethroughput.uplink.get_pcc()
Returns the expected maximum throughput (averaged over one frame) for the uplink of one component carrier. The throughput is calculated for the currently selected scheduling type.
- return:
throughput: float Unit: Mbit/s
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.sense.connection.ethroughput.uplink.clone()